Ordering no:
Female cable connector with cable clamp, shieldable, PG 7, cable outlet 4-6 mm, UL approval
Female cable connector with cable clamp, shieldable, PG 7, cable outlet 4-6 mm, UL approval, Series
Available numbers of contacts
99 5102 00 02
M16 IP67 female cable connector, Contacts: 2, 4.0 - 6.0 mm, shieldable, solder, IP67, UL
M16, series 423, Miniature connectors
Order number |
99 5102 00 02
|
Connector locking system | screw |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 18 |
Cable outlet | 4.0 - 6.0 mm |
EMC compliance | shieldable |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Temperature range from/to | – 30 °C / 95 °C |
Rated current (40 °C) | 7 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Insulation resistance | ≥ 10¹⁰ Ω |
Contact material | CuSn (bronze) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Approval 1 | UL |
Connector design | female cable connector |
Customs tariff number | 85369010 |
Weight (g) | 51.485 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Certificates
CAD files
99 5102 09 02
M16 IP67 female cable connector, Contacts: 2, 4.0 - 6.0 mm, shieldable, solder, IP67, UL
M16, series 423, Miniature connectors
Order number |
99 5102 09 02
|
Connector locking system | screw |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 18 |
Cable outlet | 4.0 - 6.0 mm |
EMC compliance | shieldable |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Temperature range from/to | – 30 °C / 95 °C |
Rated current (40 °C) | 7 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Insulation resistance | ≥ 10¹⁰ Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Approval 1 | UL |
Connector design | female cable connector |
Customs tariff number | 85369010 |
Weight (g) | 51.485 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Certificates
CAD files
99 5106 00 03
M16 IP67 female cable connector, Contacts: 3 DIN, 4.0 - 6.0 mm, shieldable, solder, IP67, UL
M16, series 423, Miniature connectors
Order number |
99 5106 00 03
|
Connector locking system | screw |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 18 |
Cable outlet | 4.0 - 6.0 mm |
EMC compliance | shieldable |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Temperature range from/to | – 30 °C / 95 °C |
Rated current (40 °C) | 7 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Insulation resistance | ≥ 10¹⁰ Ω |
Contact material | CuSn (bronze) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Approval 1 | UL |
Connector design | female cable connector |
Customs tariff number | 85369010 |
Weight (g) | 51.609 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Certificates
CAD files
99 5106 09 03
M16 IP67 female cable connector, Contacts: 3 DIN, 4.0 - 6.0 mm, shieldable, solder, IP67, UL
M16, series 423, Miniature connectors
Order number |
99 5106 09 03
|
Connector locking system | screw |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 18 |
Cable outlet | 4.0 - 6.0 mm |
EMC compliance | shieldable |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Temperature range from/to | – 30 °C / 95 °C |
Rated current (40 °C) | 7 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Insulation resistance | ≥ 10¹⁰ Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Approval 1 | UL |
Connector design | female cable connector |
Customs tariff number | 85369010 |
Weight (g) | 51.609 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Certificates
CAD files
99 5110 00 04
M16 IP67 female cable connector, Contacts: 4, 4.0 - 6.0 mm, shieldable, solder, IP67, UL
M16, series 423, Miniature connectors
Order number |
99 5110 00 04
|
Connector locking system | screw |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 18 |
Cable outlet | 4.0 - 6.0 mm |
EMC compliance | shieldable |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Temperature range from/to | – 30 °C / 95 °C |
Rated current (40 °C) | 6 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Insulation resistance | ≥ 10¹⁰ Ω |
Contact material | CuSn (bronze) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Approval 1 | UL |
Connector design | female cable connector |
Customs tariff number | 85369010 |
Weight (g) | 51.792 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Certificates
CAD files
99 5110 09 04
M16 IP67 female cable connector, Contacts: 4, 4.0 - 6.0 mm, shieldable, solder, IP67, UL
M16, series 423, Miniature connectors
Order number |
99 5110 09 04
|
Connector locking system | screw |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 18 |
Cable outlet | 4.0 - 6.0 mm |
EMC compliance | shieldable |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Temperature range from/to | – 30 °C / 95 °C |
Rated current (40 °C) | 6 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Insulation resistance | ≥ 10¹⁰ Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Approval 1 | UL |
Connector design | female cable connector |
Customs tariff number | 85369010 |
Weight (g) | 51.792 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Certificates
CAD files
99 5114 00 05
M16 IP67 female cable connector, Contacts: 5, 4.0 - 6.0 mm, shieldable, solder, IP67, UL
M16, series 423, Miniature connectors
Order number |
99 5114 00 05
|
Connector locking system | screw |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 18 |
Cable outlet | 4.0 - 6.0 mm |
EMC compliance | shieldable |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Temperature range from/to | – 30 °C / 95 °C |
Rated current (40 °C) | 6 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Insulation resistance | ≥ 10¹⁰ Ω |
Contact material | CuSn (bronze) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Approval 1 | UL |
Connector design | female cable connector |
Customs tariff number | 85369010 |
Weight (g) | 51.886 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Certificates
CAD files
99 5114 09 05
M16 IP67 female cable connector, Contacts: 5, 4.0 - 6.0 mm, shieldable, solder, IP67, UL
M16, series 423, Miniature connectors
Order number |
99 5114 09 05
|
Connector locking system | screw |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 18 |
Cable outlet | 4.0 - 6.0 mm |
EMC compliance | shieldable |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Temperature range from/to | – 30 °C / 95 °C |
Rated current (40 °C) | 6 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Insulation resistance | ≥ 10¹⁰ Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Approval 1 | UL |
Connector design | female cable connector |
Customs tariff number | 85369010 |
Weight (g) | 51.886 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Certificates
CAD files
99 5118 00 05
M16 IP67 female cable connector, Contacts: 5 (stereo), 4.0 - 6.0 mm, shieldable, solder, IP67, UL
M16, series 423, Miniature connectors
Order number |
99 5118 00 05
|
Connector locking system | screw |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 18 |
Cable outlet | 4.0 - 6.0 mm |
EMC compliance | shieldable |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Temperature range from/to | – 30 °C / 95 °C |
Rated current (40 °C) | 6 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Insulation resistance | ≥ 10¹⁰ Ω |
Contact material | CuSn (bronze) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Approval 1 | UL |
Connector design | female cable connector |
Customs tariff number | 85369010 |
Weight (g) | 51.506 |





Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Certificates
CAD files
99 5118 09 05
M16 IP67 female cable connector, Contacts: 5 (stereo), 4.0 - 6.0 mm, shieldable, solder, IP67, UL
M16, series 423, Miniature connectors
Order number |
99 5118 09 05
|
Connector locking system | screw |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 18 |
Cable outlet | 4.0 - 6.0 mm |
EMC compliance | shieldable |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Temperature range from/to | – 30 °C / 95 °C |
Rated current (40 °C) | 6 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Insulation resistance | ≥ 10¹⁰ Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Approval 1 | UL |
Connector design | female cable connector |
Customs tariff number | 85369010 |
Weight (g) | 51.511 |





Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Certificates
CAD files
99 5122 00 06
M16 IP67 female cable connector, Contacts: 6 DIN, 4.0 - 6.0 mm, shieldable, solder, IP67, UL
M16, series 423, Miniature connectors
Order number |
99 5122 00 06
|
Connector locking system | screw |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 18 |
Cable outlet | 4.0 - 6.0 mm |
EMC compliance | shieldable |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Temperature range from/to | – 30 °C / 95 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Insulation resistance | ≥ 10¹⁰ Ω |
Contact material | CuSn (bronze) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Approval 1 | UL |
Connector design | female cable connector |
Customs tariff number | 85369010 |
Weight (g) | 52.092 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Certificates
CAD files
99 5122 09 06
M16 IP67 female cable connector, Contacts: 6 DIN, 4.0 - 6.0 mm, shieldable, solder, IP67, UL
M16, series 423, Miniature connectors
Order number |
99 5122 09 06
|
Connector locking system | screw |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 18 |
Cable outlet | 4.0 - 6.0 mm |
EMC compliance | shieldable |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Temperature range from/to | – 30 °C / 95 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Insulation resistance | ≥ 10¹⁰ Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Approval 1 | UL |
Connector design | female cable connector |
Customs tariff number | 85369010 |
Weight (g) | 52.092 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Certificates
CAD files
99 5126 00 07
M16 IP67 female cable connector, Contacts: 7, 4.0 - 6.0 mm, shieldable, solder, IP67, UL
M16, series 423, Miniature connectors
Order number |
99 5126 00 07
|
Connector locking system | screw |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 18 |
Cable outlet | 4.0 - 6.0 mm |
EMC compliance | shieldable |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Temperature range from/to | – 30 °C / 95 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 125 V |
Rated impulse voltage | 800 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Insulation resistance | ≥ 10¹⁰ Ω |
Contact material | CuSn (bronze) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Approval 1 | UL |
Connector design | female cable connector |
Customs tariff number | 85369010 |
Weight (g) | 52.196 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Certificates
CAD files
99 5126 09 07
M16 IP67 female cable connector, Contacts: 7, 4.0 - 6.0 mm, shieldable, solder, IP67, UL
M16, series 423, Miniature connectors
Order number |
99 5126 09 07
|
Connector locking system | screw |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 18 |
Cable outlet | 4.0 - 6.0 mm |
EMC compliance | shieldable |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Temperature range from/to | – 30 °C / 95 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 125 V |
Rated impulse voltage | 800 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Insulation resistance | ≥ 10¹⁰ Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Approval 1 | UL |
Connector design | female cable connector |
Customs tariff number | 85369010 |
Weight (g) | 52.196 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Certificates
CAD files
99 5182 00 07
M16 IP67 female cable connector, Contacts: 7 DIN, 4.0 - 6.0 mm, shieldable, solder, IP67, UL
M16, series 423, Miniature connectors
Order number |
99 5182 00 07
|
Connector locking system | screw |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 18 |
Cable outlet | 4.0 - 6.0 mm |
EMC compliance | shieldable |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Temperature range from/to | – 30 °C / 95 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 60 V |
Rated impulse voltage | 800 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Insulation resistance | ≥ 10¹⁰ Ω |
Contact material | CuSn (bronze) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Approval 1 | UL |
Connector design | female cable connector |
Customs tariff number | 85369010 |
Weight (g) | 51.57 |





Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Certificates
CAD files
99 5172 00 08
M16 IP67 female cable connector, Contacts: 8 DIN, 4.0 - 6.0 mm, shieldable, solder, IP68, UL, AISG compliant
M16, series 423, Miniature connectors
Order number |
99 5172 00 08
|
Connector locking system | screw |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 18 |
Cable outlet | 4.0 - 6.0 mm |
EMC compliance | shieldable |
Degree of protection |
IP68 IP67 |
Mechanical operation | > 500 Mating cycles |
Temperature range from/to | – 30 °C / 95 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Insulation resistance | ≥ 10¹⁰ Ω |
Contact material | CuSn (bronze) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Approval 1 |
UL AISG compliant |
Connector design | female cable connector |
Customs tariff number | 85369010 |
Weight (g) | 51.651 |





Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Certificates
CAD files
99 5172 09 08
M16 IP67 female cable connector, Contacts: 8 DIN, 4.0 - 6.0 mm, shieldable, solder, IP68, UL, AISG compliant
M16, series 423, Miniature connectors
Order number |
99 5172 09 08
|
Connector locking system | screw |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 18 |
Cable outlet | 4.0 - 6.0 mm |
EMC compliance | shieldable |
Degree of protection |
IP68 IP67 |
Mechanical operation | > 500 Mating cycles |
Temperature range from/to | – 30 °C / 95 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Insulation resistance | ≥ 10¹⁰ Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Approval 1 |
UL AISG compliant |
Connector design | female cable connector |
Customs tariff number | 85369010 |
Weight (g) | 51.659 |





Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Certificates
CAD files
99 5130 00 12
M16 IP67 female cable connector, Contacts: 12, 4.0 - 6.0 mm, shieldable, solder, IP67, UL
M16, series 423, Miniature connectors
Order number |
99 5130 00 12
|
Connector locking system | screw |
Termination | solder |
Wire gauge (mm) | 0.25 mm² |
Wire gauge (AWG) | 24 |
Cable outlet | 4.0 - 6.0 mm |
EMC compliance | shieldable |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Temperature range from/to | – 30 °C / 95 °C |
Rated current (40 °C) | 3 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Insulation resistance | ≥ 10¹⁰ Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Approval 1 | UL |
Connector design | female cable connector |
Customs tariff number | 85369010 |
Weight (g) | 51.678 |





Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Certificates
CAD files
99 5452 00 14
M16 IP67 female cable connector, Contacts: 14, 4.0 - 6.0 mm, shieldable, solder, IP67, UL
M16, series 423, Miniature connectors
Order number |
99 5452 00 14
|
Connector locking system | screw |
Termination | solder |
Wire gauge (mm) | 0.25 mm² |
Wire gauge (AWG) | 24 |
Cable outlet | 4.0 - 6.0 mm |
EMC compliance | shieldable |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Temperature range from/to | – 30 °C / 95 °C |
Rated current (40 °C) | 3 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Insulation resistance | ≥ 10¹⁰ Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Approval 1 | UL |
Connector design | female cable connector |
Customs tariff number | 85369010 |
Weight (g) | 51.796 |





Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Certificates
CAD files
99 5462 00 19
M16 IP67 female cable connector, Contacts: 19, 4.0 - 6.0 mm, shieldable, solder, IP67, UL
M16, series 423, Miniature connectors
Order number |
99 5462 00 19
|
Connector locking system | screw |
Termination | solder |
Wire gauge (mm) | 0.25 mm² |
Wire gauge (AWG) | 24 |
Cable outlet | 4.0 - 6.0 mm |
EMC compliance | shieldable |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Temperature range from/to | – 30 °C / 95 °C |
Rated current (40 °C) | 3 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Insulation resistance | ≥ 10¹⁰ Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Approval 1 | UL |
Connector design | female cable connector |
Customs tariff number | 85369010 |
Weight (g) | 52.077 |





Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Certificates
CAD files
99 5496 00 24
M16 IP67 female cable connector, Contacts: 24, 4.0 - 6.0 mm, shieldable, solder, IP67, UL
M16, series 423, Miniature connectors
Order number |
99 5496 00 24
|
Connector locking system | screw |
Termination | solder |
Wire gauge (mm) | 0.14 mm² |
Wire gauge (AWG) | 26 |
Cable outlet | 4.0 - 6.0 mm |
EMC compliance | shieldable |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Temperature range from/to | – 30 °C / 95 °C |
Rated current (40 °C) | 1 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Insulation resistance | ≥ 10¹⁰ Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Approval 1 | UL |
Connector design | female cable connector |
Customs tariff number | 85369010 |
Weight (g) | 51.949 |





Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Certificates
CAD files
Contact to customer service
Do you have any questions regarding our products or do you wish an individual offer?