Menu
Back

Male panel mount connector, solder

M9 IP40, Male panel mount connector, solder, Series

  1. Products
  2. Subminiature connectors
  3. M9 IP40
  4. Male panel mount connector, solder
Ordering no:

Male panel mount connector, solder

Male panel mount connector, solder, Series 711
Available numbers of contacts
Compare product
09 0073 00 02
M9 IP40 male panel mount connector, Contacts: 2, shielding is not possible, solder, IP40
M9, series 711, Subminiature connectors
Technical data
Moreless
Order number 09 0073 00 02
Connector design male panel mount connector
Connector locking system screw
Termination solder
Wire gauge (mm) 0.25 mm²
Wire gauge (AWG) 24
EMC compliance shielding is not possible
Degree of protection IP40
Mechanical operation > 500 Mating cycles
Temperature range from/to -40 °C / 85 °C
Rated current (40 °C) 4 A
Rated voltage 125 V
Rated impulse voltage 1500 V
Pollution degree 1
Overvoltage category II
Insulating material group III
Insulation resistance ≥ 10¹⁰ Ω
Contact material CuZn (brass)
Contact plating Au (gold)
Contact body material PA (UL94 V-0)
REACH SVHC CAS 7439-92-1 (Lead)
Customs tariff number 85369010
Weight (g) 3.568
09 0077 00 03
M9 IP40 male panel mount connector, Contacts: 3, shielding is not possible, solder, IP40
M9, series 711, Subminiature connectors
Technical data
Moreless
Order number 09 0077 00 03
Connector design male panel mount connector
Connector locking system screw
Termination solder
Wire gauge (mm) 0.25 mm²
Wire gauge (AWG) 24
EMC compliance shielding is not possible
Degree of protection IP40
Mechanical operation > 500 Mating cycles
Temperature range from/to -40 °C / 85 °C
Rated current (40 °C) 4 A
Rated voltage 125 V
Rated impulse voltage 1500 V
Pollution degree 1
Overvoltage category II
Insulating material group III
Insulation resistance ≥ 10¹⁰ Ω
Contact material CuZn (brass)
Contact plating Au (gold)
Contact body material PA (UL94 V-0)
REACH SVHC CAS 7439-92-1 (Lead)
Customs tariff number 85369010
Weight (g) 3.648
09 0081 00 04
M9 IP40 male panel mount connector, Contacts: 4, shielding is not possible, solder, IP40
M9, series 711, Subminiature connectors
Technical data
Moreless
Order number 09 0081 00 04
Connector design male panel mount connector
Connector locking system screw
Termination solder
Wire gauge (mm) 0.25 mm²
Wire gauge (AWG) 24
EMC compliance shielding is not possible
Degree of protection IP40
Mechanical operation > 500 Mating cycles
Temperature range from/to -40 °C / 85 °C
Rated current (40 °C) 3 A
Rated voltage 125 V
Rated impulse voltage 1500 V
Pollution degree 1
Overvoltage category II
Insulating material group III
Insulation resistance ≥ 10¹⁰ Ω
Contact material CuZn (brass)
Contact plating Au (gold)
Contact body material PA (UL94 V-0)
REACH SVHC CAS 7439-92-1 (Lead)
Customs tariff number 85369010
Weight (g) 3.724
09 0097 00 05
M9 IP40 male panel mount connector, Contacts: 5, shielding is not possible, solder, IP40
M9, series 711, Subminiature connectors
Technical data
Moreless
Order number 09 0097 00 05
Connector design male panel mount connector
Connector locking system screw
Termination solder
Wire gauge (mm) 0.25 mm²
Wire gauge (AWG) 24
EMC compliance shielding is not possible
Degree of protection IP40
Mechanical operation > 500 Mating cycles
Temperature range from/to -40 °C / 85 °C
Rated current (40 °C) 3 A
Rated voltage 125 V
Rated impulse voltage 1500 V
Pollution degree 1
Overvoltage category II
Insulating material group III
Insulation resistance ≥ 10¹⁰ Ω
Contact material CuZn (brass)
Contact plating Au (gold)
Contact body material PA (UL94 V-0)
REACH SVHC CAS 7439-92-1 (Lead)
Customs tariff number 85369010
Weight (g) 3.801
09 0477 00 07
M9 IP40 male panel mount connector, Contacts: 7, shielding is not possible, solder, IP40
M9, series 711, Subminiature connectors
Technical data
Moreless
Order number 09 0477 00 07
Connector design male panel mount connector
Connector locking system screw
Termination solder
Wire gauge (mm) 0.14 mm²
Wire gauge (AWG) 26
EMC compliance shielding is not possible
Degree of protection IP40
Mechanical operation > 500 Mating cycles
Temperature range from/to -40 °C / 85 °C
Rated current (40 °C) 1 A
Rated voltage 125 V
Rated impulse voltage 1500 V
Pollution degree 1
Overvoltage category II
Insulating material group III
Insulation resistance ≥ 10¹⁰ Ω
Contact material CuZn (brass)
Contact plating Au (gold)
Contact body material PA (UL94 V-0)
REACH SVHC CAS 7439-92-1 (Lead)
Customs tariff number 85369010
Weight (g) 3.689
09 0481 00 08
M9 IP40 male panel mount connector, Contacts: 8, shielding is not possible, solder, IP40
M9, series 711, Subminiature connectors
Technical data
Moreless
Order number 09 0481 00 08
Connector design male panel mount connector
Connector locking system screw
Termination solder
Wire gauge (mm) 0.14 mm²
Wire gauge (AWG) 26
EMC compliance shielding is not possible
Degree of protection IP40
Mechanical operation > 500 Mating cycles
Temperature range from/to -40 °C / 85 °C
Rated current (40 °C) 1 A
Rated voltage 125 V
Rated impulse voltage 1500 V
Pollution degree 1
Overvoltage category II
Insulating material group III
Insulation resistance ≥ 10¹⁰ Ω
Contact material CuZn (brass)
Contact plating Au (gold)
Contact body material PA (UL94 V-0)
REACH SVHC CAS 7439-92-1 (Lead)
Customs tariff number 85369010
Weight (g) 3.728
Do you have questions regarding our products, cannot find a specific model or would like to receive a personalised offer? If so, select your country and postcode to find the appropriate contact person.
Male panel mount connector, solder
Ordering no09 0073 00 02
Male panel mount connector, solder
Ordering no09 0077 00 03
Male panel mount connector, solder
Ordering no09 0081 00 04
Male panel mount connector, solder
Ordering no09 0097 00 05
Male panel mount connector, solder
Ordering no09 0477 00 07
Male panel mount connector, solder
Ordering no09 0481 00 08