Ordering no:
Female panel mount connector, green
Female panel mount connector, green, Series 620 MED
Available numbers of contacts
99 9208 070 03
Snap-In IP67, subminiature female panel mount connector, Contacts: 3, Shielding is not possible, solder, IP67
Snap In, series 620, Connectors for medical applications
Order number |
99 9208 070 03
|
Connector locking system | snap |
Termination | solder |
Wire gauge (mm) | 0.25 mm² |
Wire gauge (AWG) | 24 |
Degree of protection | IP67 |
Upper limit temperature | 85 °C |
Lower limit temperature | -25 °C |
Rated current (40 °C) | 3 A |
Rated voltage | 125 V |
Rated impulse voltage | 1500 V |
Pollution degree | 2 |
Overvoltage category | II |
Insulating material group | II |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PA (UL 94 V-0) |
Housing material | PA |
Customs tariff number | 85369010 |
Weight (g) | 2.368 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
99 9212 070 04
Snap-In IP67, subminiature female panel mount connector, Contacts: 4, Shielding is not possible, solder, IP67
Snap In, series 620, Connectors for medical applications
Order number |
99 9212 070 04
|
Connector locking system | snap |
Termination | solder |
Wire gauge (mm) | 0.25 mm² |
Wire gauge (AWG) | 24 |
Degree of protection | IP67 |
Upper limit temperature | 85 °C |
Lower limit temperature | -25 °C |
Rated current (40 °C) | 2,5 A |
Rated voltage | 125 V |
Rated impulse voltage | 1500 V |
Pollution degree | 2 |
Overvoltage category | II |
Insulating material group | II |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PA (UL 94 V-0) |
Housing material | PA |
Customs tariff number | 85369010 |
Weight (g) | 2.512 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
99 9216 070 05
Snap-In IP67, subminiature female panel mount connector, Contacts: 5, Shielding is not possible, solder, IP67
Snap In, series 620, Connectors for medical applications
Order number |
99 9216 070 05
|
Connector locking system | snap |
Termination | solder |
Wire gauge (mm) | 0.25 mm² |
Wire gauge (AWG) | 24 |
Degree of protection | IP67 |
Upper limit temperature | 85 °C |
Lower limit temperature | -25 °C |
Rated current (40 °C) | 2 A |
Rated voltage | 63 V |
Rated impulse voltage | 800 V |
Pollution degree | 2 |
Overvoltage category | II |
Insulating material group | II |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PA (UL 94 V-0) |
Housing material | PA |
Customs tariff number | 85369010 |
Weight (g) | 2.67 |





Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
99 9228 070 08
Snap-In IP67, subminiature female panel mount connector, Contacts: 8, Shielding is not possible, solder, IP67
Snap In, series 620, Connectors for medical applications
Order number |
99 9228 070 08
|
Connector locking system | snap |
Termination | solder |
Wire gauge (mm) | 0.25 mm² |
Wire gauge (AWG) | 24 |
Degree of protection | IP67 |
Upper limit temperature | 85 °C |
Lower limit temperature | -25 °C |
Rated current (40 °C) | 1 A |
Rated voltage | 63 V |
Rated impulse voltage | 800 V |
Pollution degree | 2 |
Overvoltage category | II |
Insulating material group | II |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PA (UL 94 V-0) |
Housing material | PA |
Customs tariff number | 85369010 |
Weight (g) | 3.053 |





Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
Contact to customer service
Do you have any questions regarding our products or do you wish an individual offer?