Ordering no:
Male angled connector, cable outlet 4-6 mm, plastic model
Male angled connector, cable outlet 4-6 mm, plastic model, Series 682
Available numbers of contacts
09 0133 70 02
M16 IP40 male angled connector, Contacts: 2, 4,0 - 6,0 mm, Shielding is not possible, solder, IP40
M16, series 682, Miniature connectors
Order number |
09 0133 70 02
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Cable outlet | 4,0 - 6,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 7 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Housing material | PA |
Customs tariff number | 85369010 |
Weight (g) | 13.563 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
09 0133 79 02
M16 IP40 male angled connector, Contacts: 2, 4,0 - 6,0 mm, Shielding is not possible, solder, IP40
M16, series 682, Miniature connectors
Order number |
09 0133 79 02
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Cable outlet | 4,0 - 6,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 7 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | PA |
Customs tariff number | 85369010 |
Weight (g) | 13.405 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
09 0135 70 03
M16 IP40 male angled connector, Contacts: 3 DIN, 4,0 - 6,0 mm, Shielding is not possible, solder, IP40
M16, series 682, Miniature connectors
Order number |
09 0135 70 03
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Cable outlet | 4,0 - 6,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 7 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Housing material | PA |
Customs tariff number | 85369010 |
Weight (g) | 13.823 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
09 0135 79 03
M16 IP40 male angled connector, Contacts: 3 DIN, 4,0 - 6,0 mm, Shielding is not possible, solder, IP40
M16, series 682, Miniature connectors
Order number |
09 0135 79 03
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Cable outlet | 4,0 - 6,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 7 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | PA |
Customs tariff number | 85369010 |
Weight (g) | 13.823 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
09 0137 70 04
M16 IP40 male angled connector, Contacts: 4, 4,0 - 6,0 mm, Shielding is not possible, solder, IP40
M16, series 682, Miniature connectors
Order number |
09 0137 70 04
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Cable outlet | 4,0 - 6,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 6 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Housing material | PA |
Customs tariff number | 85369010 |
Weight (g) | 13.827 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
09 0137 79 04
M16 IP40 male angled connector, Contacts: 4, 4,0 - 6,0 mm, Shielding is not possible, solder, IP40
M16, series 682, Miniature connectors
Order number |
09 0137 79 04
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Cable outlet | 4,0 - 6,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 6 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | PA |
Customs tariff number | 85369010 |
Weight (g) | 14.025 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
09 0139 70 05
M16 IP40 male angled connector, Contacts: 5, 4,0 - 6,0 mm, Shielding is not possible, solder, IP40
M16, series 682, Miniature connectors
Order number |
09 0139 70 05
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Cable outlet | 4,0 - 6,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 6 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Housing material | PA |
Customs tariff number | 85369010 |
Weight (g) | 14.272 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
09 0139 79 05
M16 IP40 male angled connector, Contacts: 5, 4,0 - 6,0 mm, Shielding is not possible, solder, IP40
M16, series 682, Miniature connectors
Order number |
09 0139 79 05
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Cable outlet | 4,0 - 6,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 6 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | PA |
Customs tariff number | 85369010 |
Weight (g) | 14.272 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
09 0141 70 05
M16 IP40 male angled connector, Contacts: 5 (stereo), 4,0 - 6,0 mm, Shielding is not possible, solder, IP40
M16, series 682, Miniature connectors
Order number |
09 0141 70 05
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Cable outlet | 4,0 - 6,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 6 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Housing material | PA |
Customs tariff number | 85369010 |
Weight (g) | 14.266 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
09 0141 79 05
M16 IP40 male angled connector, Contacts: 5 (stereo), 4,0 - 6,0 mm, Shielding is not possible, solder, IP40
M16, series 682, Miniature connectors
Order number |
09 0141 79 05
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Cable outlet | 4,0 - 6,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 6 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | PA |
Customs tariff number | 85369010 |
Weight (g) | 14.266 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
09 0143 70 06
M16 IP40 male angled connector, Contacts: 6 DIN, 4,0 - 6,0 mm, Shielding is not possible, solder, IP40
M16, series 682, Miniature connectors
Order number |
09 0143 70 06
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Cable outlet | 4,0 - 6,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Housing material | PA |
Customs tariff number | 85369010 |
Weight (g) | 14.5 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
09 0143 79 06
M16 IP40 male angled connector, Contacts: 6 DIN, 4,0 - 6,0 mm, Shielding is not possible, solder, IP40
M16, series 682, Miniature connectors
Order number |
09 0143 79 06
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Cable outlet | 4,0 - 6,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | PA |
Customs tariff number | 85369010 |
Weight (g) | 14.5 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
09 0145 70 07
M16 IP40 male angled connector, Contacts: 7, 4,0 - 6,0 mm, Shielding is not possible, solder, IP40
M16, series 682, Miniature connectors
Order number |
09 0145 70 07
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Cable outlet | 4,0 - 6,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 125 V |
Rated impulse voltage | 800 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Housing material | PA |
Customs tariff number | 85369010 |
Weight (g) | 14.724 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
09 0145 79 07
M16 IP40 male angled connector, Contacts: 7, 4,0 - 6,0 mm, Shielding is not possible, solder, IP40
M16, series 682, Miniature connectors
Order number |
09 0145 79 07
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Cable outlet | 4,0 - 6,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 125 V |
Rated impulse voltage | 800 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | PA |
Customs tariff number | 85369010 |
Weight (g) | 14.726 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
09 0177 70 07
M16 IP40 male angled connector, Contacts: 7 DIN, 4,0 - 6,0 mm, Shielding is not possible, solder, IP40
M16, series 682, Miniature connectors
Order number |
09 0177 70 07
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Cable outlet | 4,0 - 6,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Housing material | PA |
Customs tariff number | 85369010 |
Weight (g) | 14.729 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
09 0153 70 08
M16 IP40 male angled connector, Contacts: 8 DIN, 4,0 - 6,0 mm, Shielding is not possible, solder, IP40
M16, series 682, Miniature connectors
Order number |
09 0153 70 08
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Cable outlet | 4,0 - 6,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Housing material | PA |
Customs tariff number | 85369010 |
Weight (g) | 14.945 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
09 0153 79 08
M16 IP40 male angled connector, Contacts: 8 DIN, 4,0 - 6,0 mm, Shielding is not possible, solder, IP40
M16, series 682, Miniature connectors
Order number |
09 0153 79 08
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Cable outlet | 4,0 - 6,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | PA |
Customs tariff number | 85369010 |
Weight (g) | 14.993 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
09 0147 70 12
M16 IP40 male angled connector, Contacts: 12, 4,0 - 6,0 mm, Shielding is not possible, solder, IP40
M16, series 682, Miniature connectors
Order number |
09 0147 70 12
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.25 mm² |
Wire gauge (AWG) | 24 |
Cable outlet | 4,0 - 6,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 3 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | PA |
Customs tariff number | 85369010 |
Weight (g) | 14.904 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
09 0161 70 14
M16 IP40 male angled connector, Contacts: 14, 4,0 - 6,0 mm, Shielding is not possible, solder, IP40
M16, series 682, Miniature connectors
Order number |
09 0161 70 14
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.25 mm² |
Wire gauge (AWG) | 24 |
Cable outlet | 4,0 - 6,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 3 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | PA |
Customs tariff number | 85369010 |
Weight (g) | 15.198 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
09 0185 70 16
M16 IP40 male angled connector, Contacts: 16, 4,0 - 6,0 mm, Shielding is not possible, solder, IP40
M16, series 682, Miniature connectors
Order number |
09 0185 70 16
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.25 mm² |
Wire gauge (AWG) | 24 |
Cable outlet | 4,0 - 6,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 3 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | PA |
Customs tariff number | 85369010 |
Weight (g) | 17.94 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
09 0163 70 19
M16 IP40 male angled connector, Contacts: 19, 4,0 - 6,0 mm, Shielding is not possible, solder, IP40
M16, series 682, Miniature connectors
Order number |
09 0163 70 19
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.25 mm² |
Wire gauge (AWG) | 24 |
Cable outlet | 4,0 - 6,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 3 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | PA |
Customs tariff number | 85369010 |
Weight (g) | 15.831 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Contact to customer service
Do you have any questions regarding our products or do you wish an individual offer?