Ordering no:
Male socket, solder, UL approval
Male socket, solder, UL approval, Series 423/ 723/ 425
Available numbers of contacts
Variants for number of contacts 2
Variants for number of contacts 3
Variants for number of contacts 4
Variants for number of contacts 5
Variants for number of contacts 6
Variants for number of contacts 7
Variants for number of contacts 8
Variants for number of contacts 12
Variants for number of contacts 14
Variants for number of contacts 16
Variants for number of contacts 19
Variants for number of contacts 24
09 0103 00 02
M16 IP67 male panel mount connector, Contacts: 2, Shielding is not possible, solder, IP67, UL
M16, series 723, Miniature connectors
Order number |
09 0103 00 02
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0,75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 95 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 7 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 10.232 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
Certificates
CAD files
09 0103 09 02
M16 IP67 male panel mount connector, Contacts: 2, Shielding is not possible, solder, IP67, UL
M16, series 723, Miniature connectors
Order number |
09 0103 09 02
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0,75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 95 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 7 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 10.241 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
Certificates
CAD files
09 0107 00 03
M16 IP67 male panel mount connector, Contacts: 3, Shielding is not possible, solder, IP67, UL
M16, series 723, Miniature connectors
Order number |
09 0107 00 03
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0,75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 95 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 7 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 10.473 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
Certificates
CAD files
09 0107 09 03
M16 IP67 male panel mount connector, Contacts: 3, Shielding is not possible, solder, IP67, UL
M16, series 723, Miniature connectors
Order number |
09 0107 09 03
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0,75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 95 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 7 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 10.479 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
Certificates
CAD files
09 0111 00 04
M16 IP67 male panel mount connector, Contacts: 4, Shielding is not possible, solder, IP67, UL
M16, series 723, Miniature connectors
Order number |
09 0111 00 04
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0,75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 95 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 6 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 10.711 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
Certificates
CAD files
09 0111 09 04
M16 IP67 male panel mount connector, Contacts: 4, Shielding is not possible, solder, IP67, UL
M16, series 723, Miniature connectors
Order number |
09 0111 09 04
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0,75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 95 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 6 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 10.691 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
Certificates
CAD files
09 0119 00 05
M16 IP67 male panel mount connector, Contacts: 5, Shielding is not possible, solder, IP67, UL
M16, series 723, Miniature connectors
Order number |
09 0119 00 05
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0,75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 95 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 6 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 10.925 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
Certificates
CAD files
09 0119 09 05
M16 IP67 male panel mount connector, Contacts: 5, Shielding is not possible, solder, IP67, UL
M16, series 723, Miniature connectors
Order number |
09 0119 09 05
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0,75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 95 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 6 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 10.939 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
Certificates
CAD files
09 0123 00 06
M16 IP67 male panel mount connector, Contacts: 6, Shielding is not possible, solder, IP67, UL
M16, series 723, Miniature connectors
Order number |
09 0123 00 06
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0,75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 95 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 11.172 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
Certificates
CAD files
09 0123 09 06
M16 IP67 male panel mount connector, Contacts: 6, Shielding is not possible, solder, IP67, UL
M16, series 723, Miniature connectors
Order number |
09 0123 09 06
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0,75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 95 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 11.18 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
Certificates
CAD files
09 0583 00 07
M16 IP67 male panel mount connector, Contacts: 7, Shielding is not possible, solder, IP67, UL
M16, series 723, Miniature connectors
Order number |
09 0583 00 07
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0,75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 95 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 11.396 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
Certificates
CAD files
09 0173 00 08
M16 IP67 male panel mount connector, Contacts: 8, Shielding is not possible, solder, IP67, UL
M16, series 723, Miniature connectors
Order number |
09 0173 00 08
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0,75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 95 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 11.629 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
Certificates
CAD files
09 0173 09 08
M16 IP67 male panel mount connector, Contacts: 8, Shielding is not possible, solder, IP67, UL
M16, series 723, Miniature connectors
Order number |
09 0173 09 08
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0,75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 95 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 11.625 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
Certificates
CAD files
09 0131 00 12
M16 IP67 male panel mount connector, Contacts: 12, Shielding is not possible, solder, IP67, UL
M16, series 723, Miniature connectors
Order number |
09 0131 00 12
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0,25 mm² |
Wire gauge (AWG) | 24 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 95 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 3 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 11.09 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
Certificates
CAD files
09 0453 00 14
M16 IP67 male panel mount connector, Contacts: 14, Shielding is not possible, solder, IP67, UL
M16, series 723, Miniature connectors
Order number |
09 0453 00 14
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0,25 mm² |
Wire gauge (AWG) | 24 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 95 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 3 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 11.308 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
Certificates
CAD files
09 0507 00 16
M16 IP67 male panel mount connector, Contacts: 16, Shielding is not possible, solder, IP67, UL
M16, series 723, Miniature connectors
Order number |
09 0507 00 16
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0,25 mm² |
Wire gauge (AWG) | 24 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 95 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 3 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 11.527 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
Certificates
CAD files
09 0463 00 19
M16 IP67 male panel mount connector, Contacts: 19, Shielding is not possible, solder, IP67, UL
M16, series 723, Miniature connectors
Order number |
09 0463 00 19
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0,25 mm² |
Wire gauge (AWG) | 24 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 95 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 3 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 11.856 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
Certificates
CAD files
09 0497 00 24
M16 IP67 male panel mount connector, Contacts: 24, Shielding is not possible, solder, IP67, UL
M16, series 723, Miniature connectors
Order number |
09 0497 00 24
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0,14 mm² |
Wire gauge (AWG) | 26 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 95 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 1 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 11.17 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
Certificates
CAD files
Contact to customer service
Do you have any questions regarding our products or do you wish an individual offer?