Ordering no:
Male panel mount connector, screwed from front, shielded, IP 67
Male panel mount connector, screwed from front, shielded, IP 67, Series 440
Available numbers of contacts
Variants for number of contacts 3
Variants for number of contacts 4
Variants for number of contacts 5
Variants for number of contacts 6
Variants for number of contacts 7
Variants for number of contacts 8
Variants for number of contacts 12
Variants for number of contacts 14
Variants for number of contacts 19
09 4807 81 03
Push-Pull male panel mount connector, Contacts: 3, shieldable, solder, IP67
Push Pull, series 440, Miniature connectors
Order number |
09 4807 81 03
|
Connector locking system | Push-Pull |
Termination | solder |
Wire gauge (mm) | 0,75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP67 |
Mechanical operation | > 1000 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 7 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 19.584 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
09 4811 81 04
Push-Pull male panel mount connector, Contacts: 4, shieldable, solder, IP67
Push Pull, series 440, Miniature connectors
Order number |
09 4811 81 04
|
Connector locking system | Push-Pull |
Termination | solder |
Wire gauge (mm) | 0,75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP67 |
Mechanical operation | > 1000 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 6 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 19.804 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
09 4815 81 05
Push-Pull male panel mount connector, Contacts: 5, shieldable, solder, IP67
Push Pull, series 440, Miniature connectors
Order number |
09 4815 81 05
|
Connector locking system | Push-Pull |
Termination | solder |
Wire gauge (mm) | 0,75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP67 |
Mechanical operation | > 1000 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 6 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 20.043 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
09 4819 81 06
Push-Pull male panel mount connector, Contacts: 6, shieldable, solder, IP67
Push Pull, series 440, Miniature connectors
Order number |
09 4819 81 06
|
Connector locking system | Push-Pull |
Termination | solder |
Wire gauge (mm) | 0,75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP67 |
Mechanical operation | > 1000 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 125 V |
Rated impulse voltage | 800 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 20.272 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
09 4827 81 07
Push-Pull male panel mount connector, Contacts: 7, shieldable, solder, IP67
Push Pull, series 440, Miniature connectors
Order number |
09 4827 81 07
|
Connector locking system | Push-Pull |
Termination | solder |
Wire gauge (mm) | 0,75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP67 |
Mechanical operation | > 1000 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 125 V |
Rated impulse voltage | 800 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 20.541 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
09 4831 81 08
Push-Pull male panel mount connector, Contacts: 8, shieldable, solder, IP67
Push Pull, series 440, Miniature connectors
Order number |
09 4831 81 08
|
Connector locking system | Push-Pull |
Termination | solder |
Wire gauge (mm) | 0,75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP67 |
Mechanical operation | > 1000 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 20.736 |





Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
09 4835 81 12
Push-Pull male panel mount connector, Contacts: 12, shieldable, solder, IP67
Push Pull, series 440, Miniature connectors
Order number |
09 4835 81 12
|
Connector locking system | Push-Pull |
Termination | solder |
Wire gauge (mm) | 0,25 mm² |
Wire gauge (AWG) | 24 |
Degree of protection | IP67 |
Mechanical operation | > 1000 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 3 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 19.979 |





Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
09 4839 81 14
Push-Pull male panel mount connector, Contacts: 14, shieldable, solder, IP67
Push Pull, series 440, Miniature connectors
Order number |
09 4839 81 14
|
Connector locking system | Push-Pull |
Termination | solder |
Wire gauge (mm) | 0,25 mm² |
Wire gauge (AWG) | 24 |
Degree of protection | IP67 |
Mechanical operation | > 1000 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 3 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 20.14 |





Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
09 4843 81 19
Push-Pull male panel mount connector, Contacts: 19, shieldable, solder, IP67
Push Pull, series 440, Miniature connectors
Order number |
09 4843 81 19
|
Connector locking system | Push-Pull |
Termination | solder |
Wire gauge (mm) | 0,25 mm² |
Wire gauge (AWG) | 24 |
Degree of protection | IP67 |
Mechanical operation | > 1000 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 3 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 20.616 |





Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
Contact to customer service