M9 IP67, Female angled connector injected, non-shielded, Series 702

Female angled connector injected, non-shielded

Back
Ordering no:

Female angled connector injected, non-shielded

Female angled connector injected, non-shielded, Series 702

79 1452 272 03

female angled connector overmoulded, unshielded, cable length 2 m, Contacts: 3

Order number 79 1452 272 03
Connector locking system schraub
Termination am Kabel angespritzt
Wire gauge (mm) 0,25 mm²
Wire gauge (AWG) 24
Cable length 2 m
Degree of protection IP67
Mechanical operation > 500 Steckzyklen
Upper limit temperature 70 °C
Lower limit temperature -25 °C
Rated voltage 125 V
Rated impulse voltage 1500 V
Pollution degree 1
Overvoltage category II
Insulating material group III
Rated current (40 °C) 4 A
Volume resistivity ≤ 3 mΩ
Contact material CuSn (Bronze)
Contact plating Au (Gold)
Contact body material PBT (UL 94 V-0)
Housing material PUR
Cable data
Sheath material PUR
Single-lead insulation PVC
Single-lead structure 32 x 0,1 mm
Cable sheath Ø 4.5
Conductor resistance 72Ω/Km
Temperature range, moving cable, °C from -5
Temperature range, moving cable, °C to 70
Temperature range, fixed cable, °C from -25
Temperature range, fixed cable, °C to 70
Bending radius, fixed cable Min. 22 mm
Bending radius, moving cable Min. 45 mm
Cable diameter 4.5
Customs tariff number 85444290
Weight (g) 58.62
Show more technical dataShow less technical data
79 1452 275 03

female angled connector overmoulded, unshielded, cable length 5m, Contacts: 3

Order number 79 1452 275 03
Connector locking system schraub
Termination am Kabel angespritzt
Wire gauge (mm) 0,25 mm²
Wire gauge (AWG) 24
Cable length 5 m
Degree of protection IP67
Mechanical operation > 500 Steckzyklen
Upper limit temperature 70 °C
Lower limit temperature -25 °C
Rated voltage 125 V
Rated impulse voltage 1500 V
Pollution degree 1
Overvoltage category II
Insulating material group III
Rated current (40 °C) 4 A
Volume resistivity ≤ 3 mΩ
Contact material CuSn (Bronze)
Contact plating Au (Gold)
Contact body material PBT (UL 94 V-0)
Housing material PUR
Cable data
Sheath material PUR
Single-lead insulation PVC
Single-lead structure 32 x 0,1 mm
Cable sheath Ø 4.5
Conductor resistance 72Ω/Km
Temperature range, moving cable, °C from -5
Temperature range, moving cable, °C to 70
Temperature range, fixed cable, °C from -25
Temperature range, fixed cable, °C to 70
Bending radius, fixed cable Min. 22 mm
Bending radius, moving cable Min. 45 mm
Cable diameter 4.5
Customs tariff number 85444290
Weight (g) 135
Show more technical dataShow less technical data
79 1456 272 05

female angled connector overmoulded, unshielded, cable length 2 m, Contacts: 5

Order number 79 1456 272 05
Connector locking system schraub
Termination am Kabel angespritzt
Wire gauge (mm) 0,25 mm²
Wire gauge (AWG) 24
Cable length 2 m
Degree of protection IP67
Mechanical operation > 500 Steckzyklen
Upper limit temperature 70 °C
Lower limit temperature -25 °C
Rated voltage 125 V
Rated impulse voltage 1500 V
Pollution degree 1
Overvoltage category II
Insulating material group III
Rated current (40 °C) 3 A
Volume resistivity ≤ 3 mΩ
Contact material CuSn (Bronze)
Contact plating Au (Gold)
Contact body material PBT (UL 94 V-0)
Housing material PUR
Cable data
Sheath material PUR
Single-lead insulation PVC
Single-lead structure 32 x 0,1 mm
Cable sheath Ø 5
Conductor resistance 72Ω/Km
Temperature range, moving cable, °C from -5
Temperature range, moving cable, °C to 70
Temperature range, fixed cable, °C from -25
Temperature range, fixed cable, °C to 70
Bending radius, fixed cable Min. 25 mm
Bending radius, moving cable Min. 50 mm
Cable diameter 5.0
Customs tariff number 85444290
Weight (g) 77
Show more technical dataShow less technical data
79 1456 275 05

female angled connector overmoulded, unshielded, cable length 5m, Contacts: 5

Order number 79 1456 275 05
Connector locking system schraub
Termination am Kabel angespritzt
Wire gauge (mm) 0,25 mm²
Wire gauge (AWG) 24
Cable length 5 m
Degree of protection IP67
Mechanical operation > 500 Steckzyklen
Upper limit temperature 70 °C
Lower limit temperature -25 °C
Rated voltage 125 V
Rated impulse voltage 1500 V
Pollution degree 1
Overvoltage category II
Insulating material group III
Rated current (40 °C) 3 A
Volume resistivity ≤ 3 mΩ
Contact material CuSn (Bronze)
Contact plating Au (Gold)
Contact body material PBT (UL 94 V-0)
Housing material PUR
Cable data
Sheath material PUR
Single-lead insulation PVC
Single-lead structure 32 x 0,1 mm
Cable sheath Ø 5
Conductor resistance 72Ω/Km
Temperature range, moving cable, °C from -5
Temperature range, moving cable, °C to 70
Temperature range, fixed cable, °C from -25
Temperature range, fixed cable, °C to 70
Bending radius, fixed cable Min. 25 mm
Bending radius, moving cable Min. 50 mm
Cable diameter 5.0
Customs tariff number 85444290
Weight (g) 175
Show more technical dataShow less technical data
79 1462 272 08

female angled connector overmoulded, not shielded, cable length 2 m, Contacts: 8

Order number 79 1462 272 08
Connector locking system schraub
Termination am Kabel angespritzt
Wire gauge (mm) 0,14 mm²
Wire gauge (AWG) 26
Cable length 2 m
Degree of protection IP67
Mechanical operation > 500 Steckzyklen
Upper limit temperature 70 °C
Lower limit temperature -25 °C
Rated voltage 125 V
Rated impulse voltage 1500 V
Pollution degree 1
Overvoltage category II
Insulating material group III
Rated current (40 °C) 1 A
Volume resistivity ≤ 3 mΩ
Contact material CuSn (Bronze)
Contact plating Au (Gold)
Contact body material PBT (UL 94 V-0)
Housing material PUR
Cable data
Sheath material PUR
Single-lead insulation PVC/ PE
Single-lead structure 18 x 0,10 mm
Cable sheath Ø 5
Conductor resistance 117Ω/Km
Temperature range, moving cable, °C from -5
Temperature range, moving cable, °C to 70
Temperature range, fixed cable, °C from -25
Temperature range, fixed cable, °C to 70
Bending radius, fixed cable Min. 25 mm
Bending radius, moving cable Min. 50 mm
Cable diameter 5.0
Customs tariff number 85444290
Weight (g) 68.498
Show more technical dataShow less technical data
79 1462 275 08

female angled connector overmoulded, unshielded, cable length 5m, Contacts: 8

Order number 79 1462 275 08
Connector locking system schraub
Termination am Kabel angespritzt
Wire gauge (mm) 0,14 mm²
Wire gauge (AWG) 26
Cable length 5 m
Degree of protection IP67
Mechanical operation > 500 Steckzyklen
Upper limit temperature 70 °C
Lower limit temperature -25 °C
Rated voltage 125 V
Rated impulse voltage 1500 V
Pollution degree 1
Overvoltage category II
Insulating material group III
Rated current (40 °C) 1 A
Volume resistivity ≤ 3 mΩ
Contact material CuSn (Bronze)
Contact plating Au (Gold)
Contact body material PBT (UL 94 V-0)
Housing material PUR
Cable data
Sheath material PUR
Single-lead insulation PVC/ PE
Single-lead structure 18 x 0,10 mm
Cable sheath Ø 5
Conductor resistance 117Ω/Km
Temperature range, moving cable, °C from -5
Temperature range, moving cable, °C to 70
Temperature range, fixed cable, °C from -25
Temperature range, fixed cable, °C to 70
Bending radius, fixed cable Min. 25 mm
Bending radius, moving cable Min. 50 mm
Cable diameter 5.0
Customs tariff number 85444290
Weight (g) 160
Show more technical dataShow less technical data
Contact to customer service
Do you have any questions regarding our products or do you wish an individual offer?