Menu
Back

Male cable connector, moulded, shielded, PVC

M12-A, Male cable connector, moulded, shielded, PVC, Series

  1. Products
  2. Automation technology - sensors and actuators
  3. M12-A
  4. Male cable connector, moulded, shielded, PVC
Ordering no:

Male cable connector, moulded, shielded, PVC

Male cable connector, moulded, shielded, PVC, Series 763
Available numbers of contacts
Compare product
77 3529 0000 20703-0200
M12-A male cable connector, Contacts: 3, shielded, moulded on cable, IP67, UL listed, PVC grey, 3 x 0.34 mm²
M12, series 763, Automation technology - sensors and actuators
General features
Moreless
Order number 77 3529 0000 20703-0200
Alternative order number: 79 3529 12 04
Notice
Please note that, due to the change from the old to the new order number, there may be deviations in the technical specifications. For questions about product details, please use the ‘Contact Customer Service’ form on the right.
More
Connector design male cable connector
Version connector male straight
Connector locking system screw
Termination moulded on cable
Degree of protection IP67
Cross-sectional area 0.34 mm² / AWG 22
Temperature range from/to -25 °C / 90 °C
Mechanical operation > 100 Mating cycles
Customs tariff number 85444290
Rated voltage 250 V
Rated impulse voltage 2500 V
Rated current (40 °C) 4 A
Insulation resistance ≥ 10¹⁰ Ω
Pollution degree 3
Overvoltage category II
Insulating material group II
EMC compliance shielded
Housing material PUR
Contact body material PUR
Contact material CuZn (brass)
Contact plating Au (gold)
Locking material CuZn (Brass nicke,l plated)
REACH SVHC CAS 7439-92-1 (Lead)
Cable data
Moreless
Cable length 2 m
Sheath material PVC
Single-lead insulation PVC
Halogen free No
Cable color grey
Cable diameter 5.0 mm
Single-lead structure 42x0.1 mm
Conductor resistance 57 Ω/Km (20°C)
Temperature range cable in move from/to -5°C / +105°C
Temperature range cable fixed from/to -40°C / +105°C
Bending radius, fixed cable ≥ 5 x Ø
Bending radius, moving cable ≥ 10 x Ø
Bending cycles >2 Mio.
Permitted acceleration max. 5 m/s² + 1 m/s²
Travel distance, horizontal 5 m/sec² -> 5 m
Travel distance, vertical 5 m/sec² -> 2 m
Travel speed ≤ 200 m/min (5 m horizontal distance)
Approval 1 UL listed
Low Voltage Directive 2014/35/EU (EN 60529:1991;EN 60204-1:2018)
RoHS Directive 2011/65/EU (EN 50581:2012)
77 3529 0000 20703-0500
M12-A male cable connector, Contacts: 3, shielded, moulded on cable, IP67, UL listed, PVC grey, 3 x 0.34 mm²
M12, series 763, Automation technology - sensors and actuators
General features
Moreless
Order number 77 3529 0000 20703-0500
Alternative order number: 79 3529 15 04
Notice
Please note that, due to the change from the old to the new order number, there may be deviations in the technical specifications. For questions about product details, please use the ‘Contact Customer Service’ form on the right.
More
Connector design male cable connector
Version connector male straight
Connector locking system screw
Termination moulded on cable
Degree of protection IP67
Cross-sectional area 0.34 mm² / AWG 22
Temperature range from/to -25 °C / 90 °C
Mechanical operation > 100 Mating cycles
Customs tariff number 85444290
Rated voltage 250 V
Rated impulse voltage 2500 V
Rated current (40 °C) 4 A
Insulation resistance ≥ 10¹⁰ Ω
Pollution degree 3
Overvoltage category II
Insulating material group II
EMC compliance shielded
Housing material PUR
Contact body material PUR
Contact material CuZn (brass)
Contact plating Au (gold)
Locking material CuZn (Brass nicke,l plated)
REACH SVHC CAS 7439-92-1 (Lead)
Cable data
Moreless
Cable length 5 m
Sheath material PVC
Single-lead insulation PVC
Halogen free No
Cable color grey
Cable diameter 5.0 mm
Single-lead structure 42x0.1 mm
Conductor resistance 57
Temperature range cable in move from/to -5°C / +105°C
Temperature range cable fixed from/to -40°C / +105°C
Bending radius, fixed cable ≥ 5 x Ø
Bending radius, moving cable ≥ 10 x Ø
Bending cycles >2 Mio.
Permitted acceleration max. 5 m/s² + 1 m/s²
Travel distance, horizontal 5 m/sec² -> 5 m
Travel distance, vertical 5 m/sec² -> 2 m
Travel speed ≤ 200 m/min (5 m horizontal distance)
Approval 1 UL listed
Low Voltage Directive 2014/35/EU (EN 60529:1991;EN 60204-1:2018)
RoHS Directive 2011/65/EU (EN 50581:2012)
77 3529 0000 20704-0200
M12-A male cable connector, Contacts: 4, shielded, moulded on cable, IP67, UL listed, PVC grey, 4 x 0.34 mm²
M12, series 763, Automation technology - sensors and actuators
General features
Moreless
Order number 77 3529 0000 20704-0200
Alternative order number: 79 3529 13 04
Notice
Please note that, due to the change from the old to the new order number, there may be deviations in the technical specifications. For questions about product details, please use the ‘Contact Customer Service’ form on the right.
More
Connector design male cable connector
Version connector male straight
Connector locking system screw
Termination moulded on cable
Degree of protection IP67
Cross-sectional area 0.34 mm² / AWG 22
Temperature range from/to -25 °C / 90 °C
Mechanical operation > 100 Mating cycles
Weight (g) 110
Customs tariff number 85444290
Rated voltage 250 V
Rated impulse voltage 2500 V
Rated current (40 °C) 4 A
Insulation resistance ≥ 10¹⁰ Ω
Pollution degree 3
Overvoltage category II
Insulating material group II
EMC compliance shielded
Housing material PUR
Contact body material PUR
Contact material CuZn (brass)
Contact plating Au (gold)
Locking material CuZn (Brass nicke,l plated)
REACH SVHC CAS 7439-92-1 (Lead)
Cable data
Moreless
Cable length 2 m
Sheath material PVC
Single-lead insulation PVC
Halogen free No
Cable color grey
Cable diameter 5.4 mm
Single-lead structure 42x0.1 mm
Conductor resistance 57
Temperature range cable in move from/to -5°C / +105°C
Temperature range cable fixed from/to -40°C / +105°C
Bending radius, fixed cable ≥ 5 x Ø
Bending radius, moving cable ≥ 10 x Ø
Bending cycles >2 Mio.
Permitted acceleration max. 5 m/s² + 1 m/s²
Travel distance, horizontal 5 m/sec² -> 5 m
Travel distance, vertical 5 m/sec² -> 2 m
Travel speed ≤ 200 m/min (5 m horizontal distance)
Approval 1 UL listed
Low Voltage Directive 2014/35/EU (EN 60529:1991;EN 60204-1:2018)
RoHS Directive 2011/65/EU (EN 50581:2012)
77 3529 0000 20704-0500
M12-A male cable connector, Contacts: 4, shielded, moulded on cable, IP67, UL listed, PVC grey, 4 x 0.34 mm²
M12, series 763, Automation technology - sensors and actuators
General features
Moreless
Order number 77 3529 0000 20704-0500
Alternative order number: 79 3529 17 04
Notice
Please note that, due to the change from the old to the new order number, there may be deviations in the technical specifications. For questions about product details, please use the ‘Contact Customer Service’ form on the right.
More
Connector design male cable connector
Version connector male straight
Connector locking system screw
Termination moulded on cable
Degree of protection IP67
Cross-sectional area 0.34 mm² / AWG 22
Temperature range from/to -25 °C / 90 °C
Mechanical operation > 100 Mating cycles
Weight (g) 110
Customs tariff number 85444290
Rated voltage 250 V
Rated impulse voltage 2500 V
Rated current (40 °C) 4 A
Insulation resistance ≥ 10¹⁰ Ω
Pollution degree 3
Overvoltage category II
Insulating material group II
EMC compliance shielded
Housing material PUR
Contact body material PUR
Contact material CuZn (brass)
Contact plating Au (gold)
Locking material CuZn (Brass nicke,l plated)
REACH SVHC CAS 7439-92-1 (Lead)
Cable data
Moreless
Cable length 5 m
Sheath material PVC
Single-lead insulation PVC
Halogen free No
Cable color grey
Cable diameter 5.4 mm
Single-lead structure 42x0.1 mm
Conductor resistance 57 Ω/Km (20°C)
Temperature range cable in move from/to -5°C / +105°C
Temperature range cable fixed from/to -40°C / +105°C
Bending radius, fixed cable ≥ 5 x Ø
Bending radius, moving cable ≥ 10 x Ø
Bending cycles >2 Mio.
Permitted acceleration max. 5 m/s² + 1 m/s²
Travel distance, horizontal 5 m/sec² -> 5 m
Travel distance, vertical 5 m/sec² -> 2 m
Travel speed ≤ 200 m/min (5 m horizontal distance)
Approval 1 UL listed
Low Voltage Directive 2014/35/EU (EN 60529:1991;EN 60204-1:2018)
RoHS Directive 2011/65/EU (EN 50581:2012)
77 3529 0000 20705-0200
M12-A male cable connector, Contacts: 5, shielded, moulded on cable, IP67, UL listed, PVC grey, 5 x 0.25 mm²
M12, series 763, Automation technology - sensors and actuators
General features
Moreless
Order number 77 3529 0000 20705-0200
Alternative order number: 79 3539 12 05
Notice
Please note that, due to the change from the old to the new order number, there may be deviations in the technical specifications. For questions about product details, please use the ‘Contact Customer Service’ form on the right.
More
Connector design male cable connector
Version connector male straight
Connector locking system screw
Termination moulded on cable
Degree of protection IP67
Cross-sectional area 0.25 mm² / AWG 24
Temperature range from/to -25 °C / 90 °C
Mechanical operation > 100 Mating cycles
Weight (g) 119
Customs tariff number 85444290
Rated voltage 60 V
Rated impulse voltage 1500 V
Rated current (40 °C) 4 A
Insulation resistance ≥ 10¹⁰ Ω
Pollution degree 3
Overvoltage category II
Insulating material group II
EMC compliance shielded
Housing material PUR
Contact body material PUR
Contact material CuZn (brass)
Contact plating Au (gold)
Locking material CuZn (Brass nicke,l plated)
REACH SVHC CAS 7439-92-1 (Lead)
Cable data
Moreless
Cable length 2 m
Sheath material PVC
Single-lead insulation PVC
Halogen free No
Cable color grey
Cable diameter 5.7 mm
Single-lead structure 32x0,1 mm
Conductor resistance 75 Ω/Km
Temperature range cable in move from/to -5°C / +105°C
Temperature range cable fixed from/to -40°C / +105°C
Bending radius, fixed cable ≥ 5 x Ø
Bending radius, moving cable ≥ 10 x Ø
Bending cycles >2 Mio.
Permitted acceleration max. 5 m/s² + 1 m/s²
Travel distance, horizontal 5 m/sec² -> 5 m
Travel distance, vertical 5 m/sec² -> 2 m
Travel speed ≤ 200 m/min (5 m horizontal distance)
Approval 1 UL listed
Low Voltage Directive 2014/35/EU (EN 60529:1991;EN 60204-1:2018)
RoHS Directive 2011/65/EU (EN 50581:2012)
77 3529 0000 20705-0500
M12-A male cable connector, Contacts: 5, shielded, moulded on cable, IP67, UL listed, PVC grey, 5 x 0.25 mm²
M12, series 763, Automation technology - sensors and actuators
General features
Moreless
Order number 77 3529 0000 20705-0500
Alternative order number: 79 3539 15 05
Notice
Please note that, due to the change from the old to the new order number, there may be deviations in the technical specifications. For questions about product details, please use the ‘Contact Customer Service’ form on the right.
More
Connector design male cable connector
Version connector male straight
Connector locking system screw
Termination moulded on cable
Degree of protection IP67
Cross-sectional area 0.25 mm² / AWG 24
Temperature range from/to -25 °C / 90 °C
Mechanical operation > 100 Mating cycles
Weight (g) 119
Customs tariff number 85444290
Rated voltage 60 V
Rated impulse voltage 1500 V
Rated current (40 °C) 4 A
Insulation resistance ≥ 10¹⁰ Ω
Pollution degree 3
Overvoltage category II
Insulating material group II
EMC compliance shielded
Housing material PUR
Contact body material PUR
Contact material CuZn (brass)
Contact plating Au (gold)
Locking material CuZn (Brass nicke,l plated)
REACH SVHC CAS 7439-92-1 (Lead)
Cable data
Moreless
Cable length 5 m
Sheath material PVC
Single-lead insulation PVC
Halogen free No
Cable color grey
Cable diameter 5.7 mm
Single-lead structure 32x0,1 mm
Conductor resistance 75
Temperature range cable in move from/to -5°C / +105°C
Temperature range cable fixed from/to -40°C / +105°C
Bending radius, fixed cable ≥ 5 x Ø
Bending radius, moving cable ≥ 10 x Ø
Bending cycles >2 Mio.
Permitted acceleration max. 5 m/s² + 1 m/s²
Travel distance, horizontal 5 m/sec² -> 5 m
Travel distance, vertical 5 m/sec² -> 2 m
Travel speed ≤ 200 m/min (5 m horizontal distance)
Approval 1 UL listed
Low Voltage Directive 2014/35/EU (EN 60529:1991;EN 60204-1:2018)
RoHS Directive 2011/65/EU (EN 50581:2012)
77 3529 0000 20708-0200
M12-A male cable connector, Contacts: 8, shielded, moulded on cable, IP67, UL listed, PVC grey, 8 x 0.25 mm²
M12, series 763, Automation technology - sensors and actuators
General features
Moreless
Order number 77 3529 0000 20708-0200
Connector design male cable connector
Version connector male straight
Connector locking system screw
Termination moulded on cable
Degree of protection IP67
Cross-sectional area 0.25 mm² / AWG 24
Temperature range from/to -25 °C / 90 °C
Mechanical operation > 100 Mating cycles
Weight (g) 165
Customs tariff number 85444290
Rated voltage 60 V
Rated voltage UL 30
Rated impulse voltage 800 V
Rated current (40 °C) 2 A
Insulation resistance ≥ 10¹⁰ Ω
Pollution degree 3
Overvoltage category II
Insulating material group II
EMC compliance shielded
Housing material PUR
Contact body material PUR
Contact material CuZn (brass)
Contact plating Au (gold)
Locking material CuZn (Brass nicke,l plated)
REACH SVHC CAS 7439-92-1 (Lead)
Cable data
Moreless
Cable length 2 m
Sheath material PVC
Single-lead insulation PVC
Halogen free No
Cable color grey
Cable diameter 6.8 mm
Single-lead structure 32x0,1 mm
Conductor resistance 75
Temperature range cable in move from/to -5°C / +105°C
Temperature range cable fixed from/to -40°C / +105°C
Bending radius, fixed cable ≥ 5 x Ø
Bending radius, moving cable ≥ 10 x Ø
Bending cycles >2 Mio.
Permitted acceleration max. 5 m/s² + 1 m/s²
Travel distance, horizontal 5 m/sec² -> 5 m
Travel distance, vertical 5 m/sec² -> 2 m
Travel speed ≤ 200 m/min (5 m horizontal distance)
Approval 1 UL listed
RoHS Directive 2011/65/EU (EN 50581:2012)
77 3529 0000 20708-0500
M12-A male cable connector, Contacts: 8, shielded, moulded on cable, IP67, UL listed, PVC grey, 8 x 0.25 mm²
M12, series 763, Automation technology - sensors and actuators
General features
Moreless
Order number 77 3529 0000 20708-0500
Connector design male cable connector
Version connector male straight
Connector locking system screw
Termination moulded on cable
Degree of protection IP67
Cross-sectional area 0.25 mm² / AWG 24
Temperature range from/to -25 °C / 90 °C
Mechanical operation > 100 Mating cycles
Weight (g) 165
Customs tariff number 85444290
Rated voltage 60 V
Rated voltage UL 30
Rated impulse voltage 800 V
Rated current (40 °C) 2 A
Insulation resistance ≥ 10¹⁰ Ω
Pollution degree 3
Overvoltage category II
Insulating material group II
EMC compliance shielded
Housing material PUR
Contact body material PUR
Contact material CuZn (brass)
Contact plating Au (gold)
Locking material CuZn (Brass nicke,l plated)
REACH SVHC CAS 7439-92-1 (Lead)
Cable data
Moreless
Cable length 5 m
Sheath material PVC
Single-lead insulation PVC
Halogen free No
Cable color grey
Cable diameter 6.8 mm
Single-lead structure 32x0,1 mm
Conductor resistance 75 Ω/Km
Temperature range cable in move from/to -5°C / +105°C
Temperature range cable fixed from/to -40°C / +105°C
Bending radius, fixed cable ≥ 5 x Ø
Bending radius, moving cable ≥ 10 x Ø
Bending cycles >2 Mio.
Permitted acceleration max. 5 m/s² + 1 m/s²
Travel distance, horizontal 5 m/sec² -> 5 m
Travel distance, vertical 5 m/sec² -> 2 m
Travel speed ≤ 200 m/min (5 m horizontal distance)
Approval 1 UL listed
RoHS Directive 2011/65/EU (EN 50581:2012)
Do you have questions regarding our products, cannot find a specific model or would like to receive a personalised offer? If so, select your country and postcode to find the appropriate contact person.
Male cable connector, moulded, shielded, PVC
Ordering no77 3529 0000 20703-0200
Male cable connector, moulded, shielded, PVC
Ordering no77 3529 0000 20703-0500
Male cable connector, moulded, shielded, PVC
Ordering no77 3529 0000 20704-0200
Male cable connector, moulded, shielded, PVC
Ordering no77 3529 0000 20704-0500
Male cable connector, moulded, shielded, PVC
Ordering no77 3529 0000 20705-0200
Male cable connector, moulded, shielded, PVC
Ordering no77 3529 0000 20705-0500
Male cable connector, moulded, shielded, PVC
Ordering no77 3529 0000 20708-0200
Male cable connector, moulded, shielded, PVC
Ordering no77 3529 0000 20708-0500