Part no.: 86 6620 1121 00404
M8 Female angled panel mount connector, Contacts: 4, shieldable, THT, IP67
M8-D, series 818, Automation Technology - Sensors and Actuators
General features
MorelessPart no. | 86 6620 1121 00404 |
Connector design | Female angled panel mount connector |
Type standard | DIN EN 61076-2-114 |
Version | Connector socket angled |
Connector locking system | screw |
Termination | THT |
Degree of protection | IP67 |
Temperature range from/to | -40 °C / 85 °C |
Mechanical operation | > 100 Mating cycles |
Weight (g) | 3.0 |
Customs tariff number | 85369010 |
Electrical parameters
MorelessRated voltage | 63 V DC |
Rated impulse voltage | 1500 V |
Rated current | 4.0 A |
Insulation resistance | > 108 Ω |
Pollution degree | 3 |
Insulating material group | III |
EMC compliance | shieldable |
Shield connection | Shielding plate |
Material
MorelessHousing material | Zinc die-cast nickel-plated |
Contact body material | PA yellow/green |
Contact material | CuZn (brass) / CuSn (bronze) |
Contact plating | Au (gold) |
REACH SVHC |
CAS 7439-92-1 (Lead) NK (Nicht klassifiziert) |
Classifications
MorelesseCl@ss 11.1 | 27-44-01-09 |
ETIM 9.0 | EC003569 |
Security notices
- The connectors have been developed for applications in plant engineering, control and electrical equipment construction. The user is responsible for checking whether the connectors can also be used in other areas of application.
- Plug connectors with enclosure protection IP67 and IP68 are not suitable for use under water. When used outdoors, the plug connectors must be protected separately against corrosion. For further information on the IP protection classes, please refer to the "Technical Information" download centre.
- To lock the cable connector with the device connector, the threaded ring is tightened "hand-tight" (approx. 40 cNm).