  4. M12 Female panel mount connector, Contacts: 3+PE, unshielded, screw clamp, IP68, UL, VDE, M20x1.5
Part no.: 99 0694 500 04

M12 Female panel mount connector, Contacts: 3+PE, unshielded, screw clamp, IP68, UL, VDE, M20x1.5

M12-S, series 814, Automation Technology - Voltage and Power Supply
Compare product
Downloads
General features
Moreless
Part no. 99 0694 500 04
Connector design Female panel mount connector
Type standard DIN EN IEC 61076-2-111:2018-10;VDE 0687-76-2-111:2018-10
Version Connector socket straight
Connector locking system screw
Termination screw clamp
Degree of protection IP68
Cross-sectional area max. 1.50 mm² / AWG 16
Temperature range from/to -40 °C / 85 °C
Mechanical operation > 100 Mating cycles
Weight (g) 20.50
Customs tariff number 85369010
Country of Origin DE
Rated voltage 630 V
Rated impulse voltage 6000 V
Rated current 12.0 A
Pollution degree 3
Overvoltage category III
Insulating material group III
EMC compliance unshielded
Housing material PA
Contact body material PA
Contact material CuZn (brass)
Contact plating Au (gold)
REACH SVHC CAS 7439-92-1 (Lead)
SCIP number 7d452b0c-c274-41c0-aee5-e833a6018871
eCl@ss 11.1 27-44-01-02
ETIM 9.0 EC002635
Security notices
  1. The connector must not be plugged or unplugged under load. Non-observance and improper use can result in personal injury.
  2. The connectors have been developed for applications in plant engineering, control and electrical equipment construction. The user is responsible for checking whether the connectors can also be used in other areas of application.
  3. To protect against unintentional opening of the connector, the thread between the housing and the connector head must be secured with a suitable cyanoacrylate adhesive when used in circuits with voltages dangerous to the touch. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
  4. Connectors which are used in circuits with voltages dangerous to the touch may only be installed and used by, or under the supervision of, persons with electrical engineering training, taking into account the applicable regulations and standards.
  5. Plug connectors with enclosure protection IP67 and IP68 are not suitable for use under water. When used outdoors, the plug connectors must be protected separately against corrosion. For further information on the IP protection classes, please refer to the "Technical Information" download centre.
  6. To lock the cable connector with the device connector, the threaded ring is tightened "hand-tight" (approx. 60 cNm).
  7. In the case of cable connectors with a metal threaded ring, it is imperative to ensure a connection with the PE protective contact of the appliance connector. Connecting cables between appliance connectors that are not connected to the PE contact are not permitted. The user must ensure a continuous connection of the protective earth conductor.
Downloads
Data sheet
Data sheet 99 0694 500 04
PDF
Data sheet, Data sheet 99 0694 500 04
Certificates
UL certificate
PDF, 1.05 MB
Certificates, UL certificate
Certificates
VDE certificate
PDF, 659.52 KB
REACH
99 0694 500 04
PDF
RoHS
99 0694 500 04
PDF
China RoHS
99 0694 500 04
PDF
CAD files
Select required format
M12-S
99 0694 500 04